CE Mark 3-Zone Thermal Shock Test Chamber for Automobile Parts Reliability Test
1. Thermal Shock Chambers Overview:
KOMEG thermal shock chambers meet the demands of today's environmental stress screening with proven performance in installations around the world. Our direct transfer method between hot and cold is an economical method to achieve rapid part temperature change for ESS or thermal shock.
Thermal shock test chamber is requisite testing equipment in metal, plastic, rubber, electronics and other industries. It is used for testing the material structure or composite material’s tolerance degree when exposed instantly in extremely high temperature and extremely low temperature environment continuously, so that whose chemical or physical damage due to thermal expansion and contraction can be detected in shortest time.
2. 3-Zone Thermal Shock Chambers Application:
Such chambers heretofore known include one comprising a test area
for the test sample, a high-temperature air conditioning unit
having gas outlet and intake adapted to communicate with the test
area, an outside air supplying unit having air outlet and inlet
adapted to communicate with the test area, and a low-temperature
air conditioning unit having gas outlet and intake adapted to
communicate with the test area.
The thermal shock chamber of this type is provided with three
dampers, i.e., one for opening or closing the gas outlet and intake
of the high-temperature air conditioning unit, another for the air
outlet and inlet of the outside air supplying unit, and another for
the gas outlet and intake of the low-temperature air conditioning
unit.
3. Specification
(1) KTS-A Series
Model |
| ||||||||
72A | 100A | 150A | 200A | 252A | 300A | 480A | |||
Inside size(mm) | W | 450 | 500 | 600 | 670 | 700 | 800 | 800 | |
H | 400 | 450 | 500 | 600 | 600 | 600 | 800 | ||
D | 400 | 450 | 500 | 500 | 600 | 650 | 750 | ||
Outside size(mm) | W | 1490 | 1540 | 1640 | 1720 | 1750 | 1850 | 1850 | |
H | 1790 | 1840 | 1890 | 2000 | 2000 | 2000 | 2200 | ||
D | 1600 | 1700 | 1830 | 1850 | 1930 | 1980 | 2500 | ||
Test weight | 5 | 10 | 12 | 15 | 18 | 20 | 20 | ||
Low Temp Chamber | -55ºC~-10ºC, Pre cooling time: ≤ 60 min from +20ºCto-55ºC | ||||||||
Test Chamber | -40ºC~+150ºC | ||||||||
High Temp Chamber | +60ºC~+200ºC ,Within 20 min, Pre-heating time | ||||||||
Transition time | ≤15S | ||||||||
Recovery time | High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample | ||||||||
Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample | |||||||||
≤ 5 min | |||||||||
Ambient Temp. | +5ºC~+35ºC | ||||||||
Power | AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires |
(2) KTS-B Series
Model |
| ||||||||
72B | 100B | 150B | 200B | 252B | 300B | 480B | |||
Inside size(mm) | W | 450 | 500 | 600 | 670 | 700 | 800 | 800 | |
H | 400 | 450 | 500 | 600 | 600 | 600 | 800 | ||
D | 400 | 450 | 500 | 500 | 600 | 650 | 750 | ||
Outside size(mm) | W | 1490 | 1540 | 1640 | 1720 | 1750 | 1850 | 1850 | |
H | 1790 | 1840 | 1890 | 2000 | 2000 | 2000 | 2200 | ||
D | 1600 | 1700 | 1830 | 1850 | 1930 | 1980 | 2500 | ||
Test weight(KG) | 5 | 10 | 12 | 15 | 18 | 20 | 20 | ||
Low Temp. chamber | -70ºC~-10ºC ,Pre cooling time: +20ºC~-70ºC ,≤ 60 min | ||||||||
Test. Chamber | -55ºC~+150ºC | ||||||||
High Temp. chamber temperature | +60ºC~+200ºC,Preheating time: ≤20 min | ||||||||
Transition time | ≤15S | ||||||||
Recovery time | High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample | ||||||||
Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample | |||||||||
≤ 5 min | |||||||||
Ambient Temp. | +5ºC~+35ºC | ||||||||
Power | AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires |
(3) KTS-D Series
Model |
| ||||||||
72D | 100D | 150D | 200D | 252D | 300D | 480D | |||
Inside size(mm) | W | 450 | 500 | 600 | 670 | 700 | 800 | 800 | |
H | 400 | 450 | 500 | 600 | 600 | 600 | 800 | ||
D | 400 | 450 | 500 | 500 | 600 | 650 | 750 | ||
Outside size(mm) | W | 1490 | 1540 | 1640 | 1720 | 1750 | 1850 | 1850 | |
H | 1790 | 1840 | 1890 | 2000 | 2000 | 2000 | 2200 | ||
D | 1600 | 1700 | 1830 | 1850 | 1930 | 1980 | 2500 | ||
Test weight | 5 | 10 | 12 | 15 | 18 | 20 | 20 | ||
Low Temp Chamber | -80ºC~-10ºC, Pre cooling time: ≤ 60 min from +20ºCto-80ºC | ||||||||
Test Chamber | -65ºC~+150ºC | ||||||||
High Temp Chamber | +60ºC~+200ºC ,Within 20 min, Pre-heating time | ||||||||
Transition time | ≤15S | ||||||||
Recovery time | High-Temp Exposure 30 min to reach & stabilize required hot temp of test sample | ||||||||
Low-Temp Exposure 30 min to reach & stabilize required cold temp of test sample | |||||||||
≤ 5 min | |||||||||
Ambient Temp. | +5ºC~+35ºC | ||||||||
Power | AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires |
4. Features of Different Cooling Mode for thermal shock chambers:
Since the cold chamber need huge cooling capacity for shocking, the chamber’s cooling mode is often designed as air-cooled or water-cooled.
Air-cooled type need installation environment:
The room must be equipped with exhauster and air conditioner to
make sure heat dissipation timely.
It’s applied to small power products and cool areas.
Water-cooled type need installation conditions:
The customer must prepare water pipe and water tower (located
outside) accordingly.
The water must be pure, or it will block the pipes and result in
some maintenance trouble with time going.
It’s often applied to large system with the features of better heat
dissipation, longer service time, low noise but slightly higher
price if count the fee of water tower and water pipes.
:
Packing Details:
We use PP Film wrapping the test chamber to protect the test chamber from moisture or being scratched first, then use strong plywood case for easy load and transport, and to keep the chambers from potential crash or impact.
KOMEG Technology Ind Co., Limited
ABOUT KOMEG
Founded in 1990, dedicating in environmental test equipment for over 30 years, KOMEG Technology lnd Co., Limited, is famous for its KOMEG star brand of environmental test equipment in China and overseas.
KOMEG specialize in climatic test chambers, temperature humidity test chambers, thermal shock test chambers, walk-in chambers, aging test chambers and burn-in room, drying ovens, Altitude test chamber, salt spray testers, and medical laboratory equipment, etc. During the past decades, KOMEG cooperated with and served many enterprises like Gree, Konka, Samsung, LG, Hiconiecs, BYD, Magna International, TOYOTA, Amicell, Stankomet, Premier, Hitek, UL, SGS, Intertek, etc.
KOMEG factory is located in Dongguan Songshan Lake, National Hi-Tech Industrial Development Zone, covering an area of 5, 000 sqm, with over 100 skilled employees including 30+ R&D engineers. (40 minutes from Shenzhen Baoan Airport by car; and 90 minutes from Guangzhou Baiyun Airport by car)
KOMEG also has branch office in Shenzhen.
Our Philosophy
Born for quality, test for future.
Our Aim
Better idea, better design and better quality.
KOMEG keep striving for continuous innovation, releasing no less than 5 new designs each year.
Our strong R&D team and skilled engineers and workers are the key factors for our success.
No matter standard models or customized project, we have rich experience to realize customers' requirements, so that our customers worldwide can benefit more from us when working with Komeg.
Ensure to meet your specific test standards, all key components and parts are imported famous brand from all over the world.
Thats why Desay( Apples' battery supplier, KONICA MINOLTA, SENKO,
Midea, TCL and Huawei are also among our long-term clients. With
KOMEG top brand strength, renowned reputation domestic and
overseas, our products are widely exported to Europe, America,
Southeast Asia, Africa, Oceania, etc. countries like
Russia, Germany, Korea, Singapore, Brazil, etc.
Distributors welcomed, Inquire today to get your order started.